WEDC The John Pickford Building
Loughborough University
Leicestershire LE11 3TU UK
+44 (0)1509 222885

Water, Engineering and Development Centre

1. Cleaning and disinfecting wells

Click here for the PDF of this Technical Note

Technical Notes on Drinking-water,
Sanitation and Hygiene in Emergencies

Cleaning and disinfecting wells

Flooding, earthquakes, civil unrest and other natural and man-made disasters often cause damage to hand-dug wells. This technical note sets out the actions needed to repair and rehabilitate a hand-dug well so that it can be returned to its former condition. The emergency repair and rehabilitation measures proposed are temporary and should be followed by measures for permanent rehabilitation.

Steps for cleaning and disinfection

Figure 1.1 outlines a four-step approach to cleaning and disinfecting wells after natural or man-made disasters. It is an emergency approach designed to rehabilitate wells so that they produce water of a similar quality to that supplied before the disaster (see Box 1.1). Technical Note 15 gives further information on wells contaminated by seawater.

Figure 1.1. Steps for cleaning and disinfecting wells

Figure 1.1. Steps for cleaning and disinfecting wells

Box 1.1. Water quality from hand-dug wells

Water taken from hand-dug wells is often of poor quality, mainly due to the poor construction of the above-ground elements and unhygienic methods of collecting water. The steps described here will not overcome these problems as they are designed to return the well to its original condition. Sources of further information on improving and upgrading wells are given at the bottom of the page.

Step 1: Inventory of existing wells

The disaster may have contaminated or damaged a large number of wells. The first step must be to select which wells should be repaired first. They are the ones that are used most and that are easiest to repair. The following actions should help you to make an informed selection.

Step 2: Rehabilitation and cleaning of wells

The amount of rehabilitation and cleaning required will depend on the amount of damage caused by the disaster. Typically it will include the following steps:

  1. Remove and repair/replace the pumping mechanism or lifting device.
  2. Remove polluted water and debris from the well using either buckets or pumps. Special care must be taken when using a pump to remove water from wells contaminated with seawater. (See Technical Note 15 for more details.)
  3. Repair/reline the well walls to reduce sub-surface contamination.
  4. Clean the well lining using a brush and chlorinated water (see Box 1.2).
  5. Place a 150mm layer of gravel in the base of the well to protect it from disturbance.
  6. Seal the top of the well using a clay sanitary seal (Figure 1.2).
  7. Construct a drainage apron and head wall around the well to prevent surface water, insects and rodents from entering the well. Provide a cover for the well.

Box 1.2. Calculating the chlorine dosage for disinfecting a well using High Strength Calcium Hypochlorite (HSCH)

Equipment

Calculating the chlorine dosage for disinfecting a well using High Strength Calcium Hypochlorite (HSCH)
  • 20 litre bucket
  • HSCH chlorine granules or powder

Method

  • Calculate the volume of water in the well using the formula:

Calculating the chlorine dosage for disinfecting a well using High Strength Calcium Hypochlorite (HSCH)

Where

V = volume of water in the well (m3)
D = diameter of the well (m)
h = depth of water (m)
π = 3.142

  • Fill the bucket with clear water from the well.
  • Add about 300g of HSCH and stir until dissolved.
  • For every cubic metre (m3) of water in the well add 10 litres (half bucket) of the chlorine solution.
  • Double the quantity of HSCH added if the solution is to be used for cleaning well linings or aprons.

HSCH and bleach give off chlorine gas which is a serious health hazard. Try to clean the well lining from outside the well using a long-handled brush. If you must enter the well, wear full protective clothing and a breathing apparatus and provide a strong air flow inside the well to carry away the chlorine gas.

Sealing the top of a well

Figure 1.2. Sealing the top of a well

Check turbidity and pH
Following cleaning and repair, allow the water level in the well to return to its normal level. Measure the turbidity and pH levels to check whether chlorination will be effective. This can be done using a simple method described in Box 1.3. Never chlorinate turbid water because suspended particles can protect micro-organisms. Table 1.1 outlines the reasons why pH and turbidity are important and what can be done to ensure guideline levels are met. If the turbidity of the well water is greater than 20NTU after the cleaning and rehabilitation stage, remove all water in the well once again and scrub the well lining with a strong concentration of bleach in water (Box 1.2).

Allow the well to refill with water and test the turbidity levels again.

If the water is still turbid, it is probably due either to:

Neither of these problems can be solved immediately. However, it is probably safe to allow the local community to begin using the well as the water quality should be at least as good as it was before the disaster.

Parameter WHO GDWQ* Why? Corrective action
pH 6-8 pH of 6.8-7.2 is required to reduce level of chlorine required. If pH is less than 6 add hydrated lime (calcium hydroxide) to raise pH before chlorination.
Turbidity < 5NTU

(20NTU emergency limit)
High turbidity requires more chlorine to oxidise organic matter. Check the turbidity of the water entering the well through the walls and base.

Make sure there is no contamination from the surface.

Table 1.1. Physico-chemical parameters
*GDWQ: Guidelines for drinking water quality

Box 1.3. Measuring turbidity and the pH level of water

Turbidity is the cloudiness or haziness of a fluid caused by individual particles. The measurement of turbidity, therefore, is a key test of water quality. Specialist laboratory or field equipment (a nephelometer) is required to measure turbidity accurately in Nephelometric Turbidity Units (NTU). If you do not have access to such specialist equipment, then a reasonable NTU estimate can be made using locally available materials as shown below.

Equipment

  • A clean container with a dark-coloured interior surface – such as an oil drum or a dustbin – and with a minimum depth of 50cm
  • A bucket
  • A dull brass or copper coin with an approximate diameter of 2.5cm
  • A long measuring pole or steel tape measure

Method

  1. Place the coin in the bottom of the container.
  2. Gently add water drawn from the well a little at a time (a). At regular intervals, wait for the surface of the water to calm and check to see if the coin is still visible (b). When it can no longer be seen (c), measure the depth of the water (d).
    • If the depth of the water is less than 32cm, then the turbidity is likely to be greater than 20NTU.
    • If the depth of the water is between 32 and 50cm, then the turbidity is likely to be between 10 and 20NTU.
    • If the depth of the water is greater than 50cm, then the turbidity is likely to be less than 10NTU.
  3. Measure the pH level of the water using pH paper strips (e).
Measuring turbidity and the pH level of water

Step 3: Disinfection of the well

WHO endorses the disinfection of drinking-water in emergency situations. There are various ways of doing this but the most common is chlorination as it leaves a residual disinfectant in the water after chlorination.

Chlorine has the advantage of being widely available, simple to measure and use, and it dissolves easily in water. Its disadvantages are that it is a hazardous substance (to be stored and handled with care) and that at commonly applied concentrations it is not effective against all pathogens (e.g. cysts and viruses, which require higher chlorine concentrations).

The chlorine compound most commonly used is high strength calcium hypochlorite (HSCH) in powder or granular form which contains 60-80% chlorine. Also used is sodium hypochlorite in liquid bleach or bleaching powder form. Each chlorine compound has a different amount of usable chlorine depending on the quantity of time the product has been stored or exposed to the atmosphere and the way it is made. Box 1.2 outlines methods for calculating appropriate chlorine doses for HSCH granule chlorine.

Stir the water in the well thoroughly with a long pole and then allow the water to stand for at least 30 minutes.

Further details on chlorination are given in Technical Note 11.

Step 4: Dewater the well

Following the contact period, remove all water in the well using a pump or bucket. When the well has refilled, wait a further 30 minutes and measure the chlorine concentration. If the residual chlorine concentration is less than 0.5mg/l the well is safe to use. If the concentration is greater than 0.5mg/l, remove all the water from the well again and repeat the process.

Two issues need extra care when dewatering the wells:

  1. Water with high concentration of chlorine should not flow into streams or wetlands
  2. When dewatering on coastal areas salt water intrusion should be avoided (see Technical Note 15)
Cleaning and disinfecting wells

Do not allow anyone to use the well during the cleaning process.

The water will have a strong concentration of chlorine that will give it a bad taste and smell and could be dangerous.



Further information


World Health Organisation logo

Water, Sanitation
Hygiene and Health Unit
Avenue Appia 20
1211 Geneva 27
Switzerland

T: + 41 22 791 2111
T (direct): +41 22 791 3555/3590
F (direct): + 41 22 791 4159
E: bosr@who.int
W: http://www.who.int/
water_sanitation_health


Prepared for WHO by WEDC. Authors: Sam Godfrey and Bob Reed. Series Editor: Bob Reed.
Editorial contributions, design and illustrations by Rod Shaw
Line illustrations courtesy of WEDC / IFRC. Additional graphics by Ken Chatterton.

Water, Engineering and Development Centre Loughborough University Leicestershire LE11 3TU UK
T: +44 1509 222885 F: +44 1509 211079 E: wedc@lboro.ac.uk W: http://wedc.lboro.ac.uk


WHO/WEDC 2010

Contact us

For enquiries about WEDC, email: wedc@lboro.ac.uk

Postal address:
WEDC
The John Pickford Building
Loughborough University
Loughborough
Leicestershire LE11 3TU
United Kingdom

t: +44 (0)1509 222885
f: +44 (0)1509 211079

Website maintained by: cv-webmaster@lboro.ac.uk